Analiza godišnje potrebe za energijom ventilacionog sistema pomoću modela zasnovanog na časovnim merenjima vremenskih uslova

  • Tomislav Ćutić University of Zagreb, Faculty of Mechanical Engineering and Naval Architecture, Department of Thermodynamics, Thermal and Process Engineering, Ivana Lučića 5, HR-10000 Zagreb, Croatia
  • Jakov Baleta University of Zagreb, Faculty of Mechanical Engineering and Naval Architecture, Department of Thermodynamics, Thermal and Process Engineering, Ivana Lučića 5, HR-10000 Zagreb, Croatia
  • Maksimilijan Padovan University of Zagreb, Faculty of Mechanical Engineering and Naval Architecture, Department of Thermodynamics, Thermal and Process Engineering, Ivana Lučića 5, HR-10000 Zagreb, Croatia
  • Darko Smoljan University of Zagreb, Faculty of Mechanical Engineering and Naval Architecture, Department of Thermodynamics, Thermal and Process Engineering, Ivana Lučića 5, HR-10000 Zagreb, Croatia
  • Igor Balen University of Zagreb, Faculty of Mechanical Engineering and Naval Architecture, Department of Thermodynamics, Thermal and Process Engineering, Ivana Lučića 5, HR-10000 Zagreb, Croatia

Apstrakt

U radu se analiziraju potrebe za energijom sistema za obradu ventilacionog vazduha. Urađen je model za proračun koji omogućava procenu godišnje energetske potrebe za grejanjem, vlaženjem i hlađenjem (sa odvlaživanjem), a koji je zasnovan na časovnim merenjima vremenskih uslova (spoljašnja temperatura i relativna vlažnost) i konstantnom zadatom vrednošću za temperaturu dovodnog vazduha i sadržaju vodene pare. Obavljeni su proračuni za dva različita procesa koje obavljaju klima-komore, a koji se razlikuju po tipu postavljenog sistema za vlaženje vazduha: ovlaživač sa parom ili sa vodom. Oba analizirana sistema su projektovana tako da obezbeđuju 100 000 m3/h dovodnog vazduha na temperaturi od 18 °C i sa sadržajem vodene pare od 8 g/kg tokom cele godine u Zagrebu, Hrvatska. Sistem za rekuperaciju toplote postavljen je u oba uređaja koji obezbeđuju rekuperaciju osetne toplote. Proračuni su obavljeni sa različitim koeficijentima rekuperacije toplote, nakon poređenja mesečne i godišnje potrebe za energijom za svaku komponentu dva pomenuta sistema, to jest za grejnu cevnu zmiju, rashladnu cevnu zmiju i ovlaživač. Dobijeni rezultati su kvalitativno upoređeni sa vrednostima datim u Prestandardu DIN V 18599-3.

Reference

[1] Hepbasli, A., Y. Kalinci, A review of heat pump water heating systems, Renew Sustain Energy Rev (2008).
[2] Liddament, M. W., M. Orme, Energy and ventilation, Applied Thermal Engineering 18 (1998).
[3] Orme, M., Estimates of the energy impact of ventilation and associated financial expenditures, Energy and Buildings 33 (2001).
[4] *** Energy Institute Hrvoje Požar, Energy in Croatia 2010 (Annual Energy Report), Ministry of Economy, Labour and Entrepreneurship of the Republic of Croatia, 2011, Zagreb, Croatia.
[5] Colliver, D. G., Energy Requirements for Conditioning of Ventilating Air (Technical Note AIVC 47), Air Infiltration and Ventilation Centre, 1995, Coventry, Great Britain.
[6] *** DIN (Deutsches Institut fuer Normung), Energy efficiency of buildings – Part 3: Net energy demand for air conditioning (DIN V 18599-3 Prestandard), 2007.
Objavljeno
2017-01-21
Kako citirati
ĆUTIĆ, Tomislav et al. Analiza godišnje potrebe za energijom ventilacionog sistema pomoću modela zasnovanog na časovnim merenjima vremenskih uslova. KGH – Klimatizacija, grejanje, hlađenje, [S.l.], v. 41, n. 4, p. 57-61, jan. 2017. ISSN 2560-340X. Dostupno na: <https://izdanja.smeits.rs/index.php/kgh/article/view/1411>. Datum pristupa: 12 nov. 2026
Sekcija
Tematski članci