Korištenje toplote geotermalne vode za potrebe daljinskog grijanja upotrebom visokotemperaturne toplotne pumpe
##plugins.themes.bootstrap3.article.main##
Apstrakt
U ovom radu autori su prikazali dio svojih istraživanja na utvrđivanju metoda i kriterijuma za dugoročnu upotrebu energetskih potencijala geotermalne vode za daljinsko grijanje gradova. Koeficijent iskorištenja toplote je naročito povoljan, kada se koristi visokotemperaturna toplotna pumpa (HTHP), postupkom i na način definisan u ovom radu. Za racionalno korištenje toplote geotermalne vode temperature 90 °C i zapreminskog protoka 100 l/s po jednoj bušotini, predviđa se dvostepeni prenos toplote na vodu iz sistema daljinskog grijanja: direktna razmjena toplote od temperature 90 °C do 50 °C a zatim prenos toplote u sistemu visokotemperaturne toplotne pumpe od 50 °C do 20 °C. Iskorišćena geotermalna voda temperature 20 °C ponovo se vraća u zemlju. Na ovaj način se direktnom razmjenom iskoristi 16,74 MW a u sistemu visokotemperaturne toplotne pumpe još dodatnih 15,06 MW. Ukupna termička efikasnost upotrebom HTHP povećala se skoro dva puta.
##plugins.themes.bootstrap3.article.details##
Reference
[2] Đurić, N., Geothermal Energy New Energetic Reality in the Area of Semberia, Republic of Srpska, Bosnia and Herzegovina, Karlovy Vary, Czech Republic, 10th International Mine Water Association Congress, 2008.
[3] Milivojević, M., J. Perić, Geotermalna potencijalnost Mačve, Semberije i Srema, XI Kongres geologa Jugoslavije, knjiga 5, SGD – SITGMSJ, Beograd, 1986.
[4] Milivojević, M., J. Perić, Preliminarna ocjena energetske potencijalnosti hidrogeotermalnih resursa u mezozonskoj podlozi tercijarnih sedimenata na području Semberije radi njenog korištenja za toplifikaciju Bijeljine, Rudarsko-geološki fakultet, Beograd, 1986.
[5] *** Predstudija ekonomske opravdanosti istraživanja i eksploatacije geotermalnih voda na teritoriji grada Bijeljine, Tehnički institut, Bijeljina, 2009.
[6] Malić, D., B. Đorđević, V. Valent, Termodinamika strujnih procesa, drugo izdanje, Građevinska knjiga, Beograd, 1980.
[7] Rant, Z., Termodinamika, knjiga za uk in prakso, Fakultet za strojništvo, Ljubljana, 2000.
[8] Seara, J. F., A. Pereiro, S. Bastos, J. A. Dopazo, Experimental Evaluation of Geothermal Heat Pump for Space Heating and Domestic Hot Water Simultaneous Production, Renewable Energy, Volume 48, 2012, 482–488.
[9] Huchtemann, K., D. Müller, Simulation Study on Supply Temperature Optimization in Domestic Heat pump Systems, Building and Environment, Available on line 5, September 2012.
[10] Lee, H., K. Saleh, Y. Hwang, R. Radermacher, Optimization of Novel Heat Exchanger Design for the Application to Low Temperature Lift Heat Pump, Energy, Volume 42, Issue 1, 2012, 204–212.
[11] Kim, M., Y. J. Balk, S. R. Park, K. C. Chang, H. S. Ra, Design of a High Temperature Production Heat Pump System Geothermal Water at Moderate Temperature, Current Applied Physics, Volume 10, Issue 2, 2010, 117–122.
[12] Wang, K., F. Cao, S. Wang, Z. Xing, Investigation of the Performance of a High Temperature Heat Pump Using Parallel cycles with Serial Heating on the Water Side, International Journal of Refrigeration, Volume 33, Issue 6, 2010, 1142–1151.
[13] Torhač, E., D. Goričanec, S. Andrejević, S. Saljnikov, J. Krope, New High Temperature Heat Pumps for Exploiting Low – temperature Sources, Res. J. Chem. Environ., Vol. 15, No. 2, 2011, 1–6.
[14] Grabant, K., D. Doberšek, J. Krope, D. Goričanec, Heat Transmission Processes in the Heat Pump Borehole, Journal of International Scientific Publication, Materials, Methods & Technologies, Vol. 4, Part 1, 2010, 81–91.
[15] Jotanović, M., M. Miščević, B. Kulcer, D. Goričanec, Optimal Proportion of Refrigerants in Single –Stage High – Temperature Heat Pump, International Journal of Systems Application, Engineering & Development, Issue 6, Volume 6, 2012, 365–375.
[16] Jotanović, M., G. Tadić, J. Krope, D. Goričanec, Analysis of Two – Stage High – Temperature Heat Pump Efficiency, International Journal of Systems Application, Engineering Development, Issue 5, Volume 6, 2012, 350–363.
[17] *** Mycom Europe, Reciprocating Compressor WBH Series, First Edition, March, 2006.