Analiza rada PV sistema koristeći faktor efikasnosti sistema - ηSF

##plugins.themes.bootstrap3.article.main##

Ilija Radovanović Ivan Popović

Apstrakt

Rad PV sistema je podložan raznim uticajima, koje nije uvek moguće predstaviti u analitičkoj formi. Ovi uticaji su kvanitifikovini kroz uvedeni faktor efikasnosti sistema ηSF. Faktor efikasnosti sistema je faktor koji se koristi za kompenzaciju vremenski promenljivih operativnih i fizičkih sistemskih parametara koji imaju uticaj na rad panela. Ovoj rad predstavlja analizu rada PV sistema koristeći uvedeni faktor efikasnosti sistema ηSF.


 


 

##plugins.themes.bootstrap3.article.details##

Kako citirati
RADOVANOVIĆ, Ilija; POPOVIĆ, Ivan. Analiza rada PV sistema koristeći faktor efikasnosti sistema - ηSF. Zbornik Međunarodne konferencije o obnovljivim izvorima električne energije – MKOIEE, [S.l.], v. 6, n. 1, p. 205-208, oct. 2018. Dostupno na: <https://izdanja.smeits.rs/index.php/mkoiee/article/view/3792>. Datum pristupa: 11 dec. 2018
Sekcija
Aplikacije i usluge

Reference

[1] I. Radovanović, Multi channel sensor Measurements in fog computing architecture for renewable energy sources systems monitoring, V MKOIEE Conference, Beograd, October 2017.
[2] I Popovic and I Radovanovic, Methodology for detection of photovoltaic systems underperfor-mance operation based on the correlation of irradiance estimates of neighboring systems, Journal of Renewable and Sustainable Energy, 10 (2018).
[3] P.Sathyanarayana, R. Ballal, P. S. L. Sagar, and G. Kumar, Effect of Shading on the Performance of Solar PV Panel, Energy and Power, 5(2015), 1-4.
[4] M. Mani and R. Pillai, Impact of dust on solar photovoltaic (PV) performance: Research status, challenges and recommendations, Renewable and Sustainable Energy Rev. 14, 9 (2010), 3124-3131.
[5] F. Freire, S. Melcher, C. G. Hochgraf, and S. K. Kurinec, Degradation analysis of an operating PV module on a Farm Sanctuary, J. Renewable Sustainable Energy 10 (2018).
[6] S. M. Samikannu, R. Namani, and S. K. Subramaniam, Power enhancement of partially shaded PV arrays through shade dispersion using magic square configuration, J. Renewable Sustainable Energy 8 (2016).
[7] Y. H. Chen, R. Liang, Y. Tian, and F. Wang, A novel fault diagnosis method of PV basedon power loss and I-V characteristics, IOP Conf. Ser.: Earth Environ. Sci. 40, (2016).
[8] A. Verma and S. Singhal, Solar PV Performance Parameter and Recommendation for Optimiza-tion of Performance in Large Scale Grid Connected Solar PV Plant—Case Study, J. Energy and Power source, 2 (2015), 40-53.