Hidrodinamičke karakteristike ekstrakcionih kolona tipa Šajbel

##plugins.themes.bootstrap3.article.main##

Milan Đ. Sovilj Momčilo Đ. Spasojević

Apstrakt

Ekstrakcija tečno-tečno je jedna od najčešće korišćenih separacionih operacija u hemijsko-inženjerskoj praksi. Kod ove operacije dovode se u kontakt dve nemešljive faze, pri čemu jedan ili više rastvoraka prelaze iz jedne u drugu fazu na bazi bolje rastvorljivosti.

##plugins.themes.bootstrap3.article.details##

Kako citirati
SOVILJ, Milan Đ.; SPASOJEVIĆ, Momčilo Đ.. Hidrodinamičke karakteristike ekstrakcionih kolona tipa Šajbel. Procesna tehnika, [S.l.], v. 33, n. 1, p. 20-23, sep. 2021. ISSN 2217-2319. Dostupno na: <https://izdanja.smeits.rs/index.php/procteh/article/view/6661>. Datum pristupa: 17 oct. 2021
Sekcija
Tema broja

Reference

[1] Treybal, R. E. Mass Transfer Operations, Mc-Graw Hill Edition,Third Edition, Auckland-Tokyio (1981), pp. 541-557. TP156.M3T7 1980 660.2 8422 78-27876ISBN 0-07- 065, J 76·0.
[2] Sovilj, M. N. Diffusion Operations, Faculty of Technology, Novi Sad (2004), pp. 173-192.(in Serbian), ISBN: 86-80995-47-9.
[3] Perry, R. H., Green, D. W. Eds. in Perry`s Chemical Engineers’ Handbook 7th Ed., McGraw-Hill Company, Inc, New York (1997), pp. 15-22 ÷ 15-46.
[4] Sovilj, M. N., Nikolovski, B. G., Spasojević, M. Đ. (2019), Hydrodynamics in Spray and Packed Liquid-Liquid Extraction Columns: A Review. Maced. J. Chem. Chem. Eng. 37 (2), 267- 182. DOI: 10.20450/mjcce.2019.1519.
[5] Sovilj, M. N., Spasojević, M. Đ. (2020), Hydrodynamics of Pulsed Sieve-Plate Extraction Columns, Hem. Ind. 74 (1), 1-14 (in Serbian), UDK: 66061.35+66.023:551.511.32.
[6] Sovilj M. N., Spasojević, M. Đ. (2020), Hydrodynamic Characteristics of Pulsed Packed Extraction Columns, Adv. Technol., 9 (1), 80-90. UDC 532.5:66.061.35.
[7] Sovilj, M. N., Spasojević, M. Đ. (2020), Characteristic of Mass Transfer in Pulsed Sieve-Plate Extraction Columns, Procesna Tehnika, 32 (1), 8-16. (in Serbian), https://izdanja.smeits.rs/index.php/procteh/article/view/6064.
[8] Sovilj, M. N., Spasojević, M. Đ. , Milivojević, N. B. (2020), Hydrodynamics of Rotation Disc Contactor Extraction Columns, Procesna Tehnika, 32 (2), 20-25 (in Serbian), https://izdanja.smeits.rs/index.php/procteh/article/view/6191.
[9] Koch Modular Process Systems, LLC., Suite 350 Paramus, NJ 07652.
[10] Bonnet Rodriguez, J. C. (1982), Hydrodynamics and Mass Transfer Studies in a Scheibel Extractor, Ph. D. Theses, Aston University, Birgingham, Uk.
[11] Yih, S.M., Wu, Y. M., Pan, Y.F. , Wu, Y. F. , Chen, T. F. (1978), Holdup Measurements in a Scheibel Extraction Column, Solvent Ext. Ion Exch. 5, (2), 353-363. https://doi.org/10.1080/07366298708918572.
[12] Bonnet, J. C., Sorrentino, J. A., (1994), Holdup measurements in a Scheibel column by means of an ultrasonic technique, Chem. Technol. Biotechnol. 61 (3), 201-207. https://doi.org/10.1002/jctb.280610304.
[13] Alatiqi, I., Aly, G., Mjalli, F. , Mumford, C. J. (1995), Mathematical Modeling and Steady-State Analysis of a Scheibel Extraction Column, Can. J. Chem. Eng. 1995, 73, 523-533. https://doi.org/10.1002/cjce.5450730413.
[14] Yuan, S., Shi, Y., Yin, H., Chen., Z., Zhou, J. (2012), Correlation of the Drop Size in a Modified Scheibel Extraction Column, Chem. Eng. Technol. 35 (10), 1810-1818. https://doi.org/10.1002/ceat.201100470.
[15] Yuan, Sh., Jin, Sh., Chen, Z. , Yuan, Y. , Jin, H. (2014) , An Improved Correlation of the Mean Drop Size in a Modified Scheibel Extraction Column, Chem. Eng. Technol. 37 (12), 2165-2174. https://doi.org/10.1002/ceat.201300873.
[16] Houshyar, Sh. Torab-Mostaedi, M., Mousavi, S. H. (2017), Prediction of Dispersed Phase Holdup in Scheibel Extraction Columns by a New Correlation, J. Chem. Petrol. Eng. 51 (2), 105-111.
[17] Bonnet, J. C. , Jeffreys, G. V. (1985), Hydrodynamics and Mass Transfer Characteristics of a Scheibel Extractor. Part I: Drop Size Distribution, Holdup, and Flooding, AIChE J. 31 (5), 788-794. https://doi.org/10.1002/aic.690310513.